logo
उत्पादों
समाचार विवरण
घर > समाचार >
Endress Hauser Promag H 300 DN65 Hygienic Flowmeter for High Throughput Filling Lines in Stock
घटनाएँ
हमसे संपर्क करें
Mrs. yuna
86-755-26850716
वीचैट 13590622754
अब संपर्क करें

Endress Hauser Promag H 300 DN65 Hygienic Flowmeter for High Throughput Filling Lines in Stock

2026-10-19
Latest company news about Endress Hauser Promag H 300 DN65 Hygienic Flowmeter for High Throughput Filling Lines in Stock

DN65 Promag H 300 Stocked for High-Throughput Filling and Dairy Mains

October 2026 — The largest bore in our current stocking position is the DN65 (2-1/2 inch) Endress+Hauser Proline Promag H 300, order code 5H3B65-AAIBAEAFBAFDCS0BA2. At this size the question is no longer resolution but throughput: how much product the line can move before the meter costs pressure, and how fast a filling head can be recommissioned after a product change.

Dairy, juice and beverage mains that feed high-speed fillers usually run close to their hydraulic limit. Any constriction in the measuring point is paid for continuously, in pump energy and in reduced filling rate. A full-bore electromagnetic sensor with a PFA liner avoids that trade-off entirely.

Throughput and pressure loss

  • Full-bore design, no cross-section constriction, so line pressure is spent on product rather than on the sensor
  • Series measuring span reaches 600 cubic metres per hour, with the achievable band set by the DN65 bore
  • Bidirectional measurement independent of pressure, density, temperature and viscosity, so recipe changes need no recalibration
  • No rotating parts and no shaft seal, which matters where oxygen pickup has to be avoided in beer and beverage transfer

Commissioning and washdown

The compact dual-compartment transmitter has a backlit display with touch control and WLAN access, so parameters can be set from a tablet without opening the housing — useful when the instrument is mounted high on a silo line. Access is from one side, the housing is rated up to IP69 for washdown areas, and a remote display variant is available for instruments installed inside cladding or on a mezzanine. Heartbeat Technology produces a verification record for QA without dismantling the line.

Order code5H3B65-AAIBAEAFBAFDCS0BA2
Nominal diameterDN65 (2-1/2 in)
Series measuring span0.06 dm³/min to 600 m³/h
Measurement error±0.5 % o.r. ±1 mm/s standard
Liner / electrodesPFA / 1.4435 (316L), Alloy C22, tantalum, platinum
Medium temperature–20 to +150 °C
Max. process pressurePN 40, Class 150, 20K
HousingCompact hygienic dual compartment, IP69

Typical installations

Milk, cream, whey and cultured product mains; juice, concentrate and syrup transfer into blending or filling; CIP return headers on large tanks and silos; and brewery transfer lines where the sensor sits between a fermenter and a centrifuge. In each case the same reasoning applies: the instrument should not be the narrowest point in the line.

Service and spares

The unit is delivered new against the order code above, in original factory packaging, with a 12-month warranty. Seals, grounding rings and connection adapters are available as separate items — send the serial number and we will match the correct spare rather than guess from a photograph. Stock normally ships in three to five working days, with factory builds at roughly six to eight weeks.

Contact our instrumentation team for stock confirmation, datasheets and lead times.

उत्पादों
समाचार विवरण
Endress Hauser Promag H 300 DN65 Hygienic Flowmeter for High Throughput Filling Lines in Stock
2026-10-19
Latest company news about Endress Hauser Promag H 300 DN65 Hygienic Flowmeter for High Throughput Filling Lines in Stock

DN65 Promag H 300 Stocked for High-Throughput Filling and Dairy Mains

October 2026 — The largest bore in our current stocking position is the DN65 (2-1/2 inch) Endress+Hauser Proline Promag H 300, order code 5H3B65-AAIBAEAFBAFDCS0BA2. At this size the question is no longer resolution but throughput: how much product the line can move before the meter costs pressure, and how fast a filling head can be recommissioned after a product change.

Dairy, juice and beverage mains that feed high-speed fillers usually run close to their hydraulic limit. Any constriction in the measuring point is paid for continuously, in pump energy and in reduced filling rate. A full-bore electromagnetic sensor with a PFA liner avoids that trade-off entirely.

Throughput and pressure loss

  • Full-bore design, no cross-section constriction, so line pressure is spent on product rather than on the sensor
  • Series measuring span reaches 600 cubic metres per hour, with the achievable band set by the DN65 bore
  • Bidirectional measurement independent of pressure, density, temperature and viscosity, so recipe changes need no recalibration
  • No rotating parts and no shaft seal, which matters where oxygen pickup has to be avoided in beer and beverage transfer

Commissioning and washdown

The compact dual-compartment transmitter has a backlit display with touch control and WLAN access, so parameters can be set from a tablet without opening the housing — useful when the instrument is mounted high on a silo line. Access is from one side, the housing is rated up to IP69 for washdown areas, and a remote display variant is available for instruments installed inside cladding or on a mezzanine. Heartbeat Technology produces a verification record for QA without dismantling the line.

Order code5H3B65-AAIBAEAFBAFDCS0BA2
Nominal diameterDN65 (2-1/2 in)
Series measuring span0.06 dm³/min to 600 m³/h
Measurement error±0.5 % o.r. ±1 mm/s standard
Liner / electrodesPFA / 1.4435 (316L), Alloy C22, tantalum, platinum
Medium temperature–20 to +150 °C
Max. process pressurePN 40, Class 150, 20K
HousingCompact hygienic dual compartment, IP69

Typical installations

Milk, cream, whey and cultured product mains; juice, concentrate and syrup transfer into blending or filling; CIP return headers on large tanks and silos; and brewery transfer lines where the sensor sits between a fermenter and a centrifuge. In each case the same reasoning applies: the instrument should not be the narrowest point in the line.

Service and spares

The unit is delivered new against the order code above, in original factory packaging, with a 12-month warranty. Seals, grounding rings and connection adapters are available as separate items — send the serial number and we will match the correct spare rather than guess from a photograph. Stock normally ships in three to five working days, with factory builds at roughly six to eight weeks.

Contact our instrumentation team for stock confirmation, datasheets and lead times.

साइट मैप |  गोपनीयता नीति | चीन अच्छा गुणवत्ता जीई बेंटली नेवादा आपूर्तिकर्ता. कॉपीराइट © 2021-2026 GREAT SYSTEM INDUSTRY CO. LTD . सब सभी अधिकार सुरक्षित.